Suchergebnisse für AirRay Electrodes — 45 Artikel

How °AirRay Electrodes Are Produced

For our vision to build active implants for recording and stimulating of brain activity, we have developed most of the technological components ourselves – such as our °AirRay electrodes. The manufacturing process offers flexible design options and has evolved over the years.

(more…)

How to Implant °AirRay Tunnel Cuff Electrodes

°AirRay Cuff electrodes make contact with peripheral nerves. These can also be very finely structured, so that the electrodes interfacing them may only have a diameter of 100 µm. The implantation of the cuff represents a big challenge in these small dimensions.

In a short video we have compiled a few tips around the implantation of Cuff electrodes – in this case especially for the °AirRay Tunnel Cuff. In order to demonstrate how cuff and nerve interact served ourselves in the kitchen and got the perfect nerve substitute – spaghettini al dente.

(more…)

Tutorial – How to Unbox Your Electrodes

With a thickness down to 0.08 mm our °AirRay Electrode Technology offers refined products for your application. Depending on the design you choose for your specific application the electrode can be very delicate in its structure which you should consider when handling.

The first step to a successful use is unboxing your electrodes. In a short video our expert for grid electrodes, Miguel Ulloa, demonstrates how to remove the electrode from the box without damaging its fine structures.

Click here to watch the video.

For more information on our electrode technology please visit our Solutions Page.
Do you need inspiration for your specific application? Explore or established designs or reach out to us with your custom design request.

Electrodes Tailored to your Application: Adjustable Degrees of Flexibility

Our °AirRay Electrode Technology allows us to manufacture electrodes that are tailored to your specific needs. The degree of flexibility of the electrodes plays an important role for many applications.

(more…)

Wireless Neuromodulation with CorTec Cuff Electrodes and novel ‘Electroparticles’

One of the major sources for complications in chronic neuromodulation are the wires connecting the different parts of the systems, or even penetrating the skin. They account for frequent device failures due to wire breaks and, especially when penetrating the skin, are a permanent risk of tissue irritations or infections.

(more…)

Electrostimulation with CorTec Cuff Electrodes Inhibits New-onset Autoimmune Diabetes

Type 1 diabetes is an autoimmune disease for which no causal cure exists to date. The only treatment method available consists of closely monitoring blood sugar levels and injecting insulin several times a day. This treatment, however, does not eliminate the cause of the disease, has to be kept up for the patient’s whole life, and comes with frequent complications, as blood sugar levels can reach critical levels when insulin injections are not optimally adjusted.

(more…)

Retrospective Webinar: Using Cuff Electrodes to Study the Peripheral Nervous System

The research in the peripheral nervous system towards new therapies based the approach of bioelectronic medicine has experienced a strong upswing in recent years. In a webinar featuring some users of our cuff electrodes we have presented challenges of this work together with recent successes.

(more…)

°AirRay Research Split Cylinder Electrode

Specifications

Product Type Implantation Site Substrate Contact Material
Electrode PNS PNS Silicone Platinum-Iridium
Product Features Product Configuration
Number of contacts Starting from 2
Inner Diameter 1.5 – 9.0 mm
Wall thickness 0.2 – 0.8 mm

Connectivity Options

Recommended Connectors
Open Cable Ends

 

Please contact us if you are interested in any other connectivity.

Options for Chronic Use

Collage_Chronic_Use_600x120

Cable Protection

Routing the electrode cables as a strain relief is advisable for chronic applications. To optimize the handling of cables we are offering flexible tubing which bundles up separate straight or coiled wires while serving as well as a protection against bending and stretching loads.

Transcutaneous Connectors

Connecting the electrode to headstages or other transmitting systems is common practice in chronic scenarios. For cuff electrodes very small connector systems like Craggs connectors are required which can be easily routed away from the nerve. We are equipping our electrode with the connectors of your choice.

Testing

Determining electrode features like electrical or mechanical properties helps to plan experiments as it allows for precisely classifying the results. We are offering different electrode-specific tests such as impedance spectroscopies, cyclic voltammograms, mechanical loads etc.

Cleaning & Sterilization

Ensuring long-term tolerability of the electrodes can be enhanced by intense cleaning and subsequent sterilization of the electrodes. We are offering clean room cleaning, sterile packaging and sterilization. Upon request we can also validate the sterilization and packaging process of the individual electrode design.

Data Sheet

All specifications of this product at a glance:

°AirRay research Split Cylinder Cuff – Data Sheet

Sales Contact

You are interested in this product? You would like to have a different product configuration?

Contact us:

sales@cortec-neuro.com

+49 761 70 888 200

Catalogue

Here you can find detailed information on all of our products.

Download our latest catalogue

References

You would like to hear a second opinion?

Read more about the experiences of our customers with our products and services in our Reference Section.

Custom Designs

This product does not match the exact specifications that you have in mind?
Contact us for custom designs! We are happy to assist you.
Learn more about custom designs

Order Form for Micro Cuff Electrodes

You are interested in our solutions for the peripheral nervous system?

Fill out our Order Form for Micro Cuff Electrodes with your specific design request and send it to sales@cortec-neuro.com.

Read our White Paper on Cuff Electrodes!

Get basic information about working in the peripheral nervous system plus additional tips for using cuff electrodes.

Go to the Download.

°AirRay Research Hook Cuff

Typical Specifications

Contact Material Inner Ø (mm) Number of Contacts Cuff Length (mm)
Platinum Iridium startin from 0.1 mm starting from 2 startin from 1.0

Connectivity Options

Recommended Connectors
Open Cable Ends

 

Please contact us if you are interested in any other connectivity.

Options for Chronic Use

Collage_Chronic_Use_600x120

Cable Protection

Routing the electrode cables as a strain relief is advisable for chronic applications. To optimize the handling of cables we are offering flexible tubing which bundles up separate straight or coiled wires while serving as well as a protection against bending and stretching loads.

Transcutaneous Connectors

Connecting the electrode to headstages or other transmitting systems is common practice in chronic scenarios. For cuff electrodes very small connector systems like Craggs connectors are required which can be easily routed away from the nerve. We are equipping our electrode with the connectors of your choice.

Testing

Determining electrode features like electrical or mechanical properties helps to plan experiments as it allows for precisely classifying the results. We are offering different electrode-specific tests such as impedance spectroscopies, cyclic voltammograms, mechanical loads etc.

Cleaning & Sterilization

Ensuring long-term tolerability of the electrodes can be enhanced by intense cleaning and subsequent sterilization of the electrodes. We are offering clean room cleaning, sterile packaging and sterilization. Upon request we can also validate the sterilization and packaging process of the individual electrode design.

Data Sheet

All specifications of this product at a glance:

°AirRay research Hook Cuff – Data Sheet

Sales Contact

You are interested in this product? You would like to have a different product configuration?

Contact us:

sales@cortec-neuro.com

+49 761 70 888 200

Catalogue

Here you can find detailed information on all of our products.

Download our latest catalogue

References

You would like to hear a second opinion?

Read more about the experiences of our customers with our products and services in our Reference Section.

Custom Designs

This product does not match the exact specifications that you have in mind?
Contact us for custom designs! We are happy to assist you.
Learn more about custom designs

Order Form for Micro Cuff Electrodes

You are interested in our solutions for the peripheral nervous system?

Fill out our Order Form for Micro Cuff Electrodes with your specific design request and send it to sales@cortec-neuro.com.

Read our White Paper on Cuff Electrodes!

Get basic information about working in the peripheral nervous system plus additional tips for using cuff electrodes.

Go to the Download.

°AirRay research Helix Cuff

Specifications

Product Type Implantation Site Substrate Contact Material
Electrode PNS PNS Silicone Platinum-Iridium
Product Features Product Configuration
Number of contacts Starting from 3
Inner Diameter 1.5 – 5.0 mm

Connectivity Options

Recommended Connectors
Open Cable Ends

 

Please contact us if you are interested in any other connectivity.

Options for Chronic Use

Collage_Chronic_Use_600x120

Cable Protection

Routing the electrode cables as a strain relief is advisable for chronic applications. To optimize the handling of cables we are offering flexible tubing which bundles up separate straight or coiled wires while serving as well as a protection against bending and stretching loads.

Transcutaneous Connectors

Connecting the electrode to headstages or other transmitting systems is common practice in chronic scenarios. For cuff electrodes very small connector systems like Craggs connectors are required which can be easily routed away from the nerve. We are equipping our electrode with the connectors of your choice.

Testing

Determining electrode features like electrical or mechanical properties helps to plan experiments as it allows for precisely classifying the results. We are offering different electrode-specific tests such as impedance spectroscopies, cyclic voltammograms, mechanical loads etc.

Cleaning & Sterilization

Ensuring long-term tolerability of the electrodes can be enhanced by intense cleaning and subsequent sterilization of the electrodes. We are offering clean room cleaning, sterile packaging and sterilization. Upon request we can also validate the sterilization and packaging process of the individual electrode design.

Data Sheet

All specifications of this product at a glance:

°AirRay research Helix Cuff – Data Sheet

Sales Contact

You are interested in this product? You would like to have a different product configuration?

Contact us:

sales@cortec-neuro.com

+49 761 70 888 200

Catalogue

Here you can find detailed information on all of our products.

Download our latest catalogue

References

You would like to hear a second opinion?

Read more about the experiences of our customers with our products and services in our Reference Section.

Custom Designs

This product does not match the exact specifications that you have in mind?
Contact us for custom designs! We are happy to assist you.
Learn more about custom designs

Order Form for Micro Cuff Electrodes

You are interested in our solutions for the peripheral nervous system?

Fill out our Order Form for Micro Cuff Electrodes with your specific design request and send it to sales@cortec-neuro.com.

Read our White Paper on Cuff Electrodes!

Get basic information about working in the peripheral nervous system plus additional tips for using cuff electrodes.

Go to the Download.